FOLLOWUS
Key Laboratory of Laser Life Science, Ministry of Education, South China Normal University,Guangzhou,China
纸质出版日期:2015,
网络出版日期:2014-5-26,
Scan for full text
Jiang, Yf., Chen, Cs., Liu, Xm. et al. Light propagation along the pericardium meridian at human wrist as evidenced by the optical experiment and Monte Carlo method., Chin. J. Integr. Med. 21, 254–258 (2015). https://doi.org/10.1007/s11655-014-1684-y
Yi-fan Jiang, Chang-shui Chen, Xiao-mei Liu, et al. Light propagation along the pericardium meridian at human wrist as evidenced by the optical experiment and Monte Carlo method[J]. Chinese Journal of Integrative Medicine, 2015,21(4):254-258.
Jiang, Yf., Chen, Cs., Liu, Xm. et al. Light propagation along the pericardium meridian at human wrist as evidenced by the optical experiment and Monte Carlo method., Chin. J. Integr. Med. 21, 254–258 (2015). https://doi.org/10.1007/s11655-014-1684-y DOI:
Yi-fan Jiang, Chang-shui Chen, Xiao-mei Liu, et al. Light propagation along the pericardium meridian at human wrist as evidenced by the optical experiment and Monte Carlo method[J]. Chinese Journal of Integrative Medicine, 2015,21(4):254-258. DOI: 10.1007/s11655-014-1684-y.
To explore the characteristics of light propagation along the Pericardium Meridian and its surrounding areas at human wrist by using optical experiment and Monte Carlo method. An experiment was carried out to obtain the distribution of diffuse light on Pericardium Meridian line and its surrounding areas at the wrist
and then a simplified model based on the anatomical structure was proposed to simulate the light transportation within the same area by using Monte Carlo method. The experimental results showed strong accordance with the Monte Carlo simulation that the light propagation along the Pericardium Meridian had an advantage over its surrounding areas at the wrist. The advantage of light transport along Pericardium Merdian line was related to components and structure of tissue
also the anatomical structure of the area that the Pericardium Meridian line runs.
To explore the characteristics of light propagation along the Pericardium Meridian and its surrounding areas at human wrist by using optical experiment and Monte Carlo method. An experiment was carried out to obtain the distribution of diffuse light on Pericardium Meridian line and its surrounding areas at the wrist
and then a simplified model based on the anatomical structure was proposed to simulate the light transportation within the same area by using Monte Carlo method. The experimental results showed strong accordance with the Monte Carlo simulation that the light propagation along the Pericardium Meridian had an advantage over its surrounding areas at the wrist. The advantage of light transport along Pericardium Merdian line was related to components and structure of tissue
also the anatomical structure of the area that the Pericardium Meridian line runs.
meridiansMonte Carlo methodopticalbiophysics
meridiansMonte Carlo methodopticalbiophysics
Yaroslavsky AN, Schulze PC, Yaroslavsky IV, Schober R, Ulrich F, Schwarzmaier HJ. Optical properties of selected native and coagulated human brain tissues in vitro in the visible and near infrared spectral range. Phys Med Biol 2002;47:2059–2073.
Saetchnikov V, Tcherniavskaia E. Analysis of the biochemical composition of biological tissue in vivo by the diffuse light scattering method. J Appl Spectrosc 2011;77:878–886.
Li H, Weng CC, Xu LQ, Xie SS. Noninvasive method to determine the optical property of biological tissue by ultrasound modulation and diffuse reflection light. Proc. SPIE 5630, Optics in Health Care and Biomedical Optics: Diagnostics and Treatment II (Chin) 2005:101–104.
Colak SB, van der Mark MB, Hooft GW, Hoogenraad JH, van der Linden ES, Kuijpers FA. Clinical optical tomography and NIR spectroscopy for breast cancer detection. IEEE J Sel Top Quantum Electron 1999;5:1143–1158.
Ahn AC, Colbert AP, Anderson BJ, Martinsen OG, Hammerschlag R, Cina S, et al. Electrical properties of acupuncture points and meridians: a systematic review. Bioelectromagnetics 2008;29:245–256.
Darras J, Albaréde P, de Vernejoul P. Nuclear medicine investigation of transmission of acupuncture information. Acupunct Med 1993;11:22–28.
Hu XL, Jin-Sen X, Wang PQ, Xu XY, Gao LY, Wu BH. Preliminary exploration on the mechanism underlying the formation of infrared radiant track along meridian courses over human body surface. J Infrared Millim Waves (Chin) 2003;22:175–180.
Roggan A, Friebel M, Dorschel K, Hahn A, Muller G. Optical properties of circulating human blood in the wavelength range 400–2500 nm. J Biomed Opt 1999;4:36–46.
Yan Z, Shi Y, Wang Y. Investigation on the biophysical features of strong luminescence phenomena in the 14 channel of human body. Acupunct Res (Chin) 1989;14:389.
Yang HQ, Xie SS, Liu SH, Li H, Guo ZY. Differences in optical transport properties between human meridian and non-meridian. Am J Chin Med 2007;35:743–752.
Liu X, Chen C, Yu J, Jiang Y, Liu S. Study on optical transport of pericardium meridian and surrounding nonmeridian tissue before and after moxibustion. Chin J Lasers (Chin) 2011;38:0404003–0404005.
Wang Y, Yang H, Xie S, Li H. Experimental measurement of the optical transport along human meridian direction. Chin J Lasers (Chin) 2009;36:2443–2447.
Wilson BC, Adam G. A Monte Carlo model for the absorption and flux distributions of light in tissue. Med Phys 1983;10:824–831.
Bilenca A, Desjardins A, Bouma BE, Tearney GJ. Multicanonical Monte-Carlo simulations of light propagation in biological media. Optics Express 2005;13:9822–9833.
Botta F, Mairani A, Battistoni G, Cremonesi M, Di Dia A, Fasso A, et al. Calculation of electron and isotopes dose point kernels with FLUKA Monte Carlo code for dosimetry in nuclear medicine therapy. Med Phys 2011;38:3944–3954.
Maeda T, Arakawa N, Takahashi M, Aizu Y. Monte Carlo simulation of spectral reflectance using a multilayered skin tissue model. Optical Review 2010;17:223–229.
McCollough CH, Schueler BA. Calculation of effective dose. Med Phys 2000;27:828–837.
Location of points. GB-12346-90, General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China.
Bashkatov AN, Genina EA, Kochubey VI, Tuchin VV. Optical properties of human skin, subcutaneous and mucous tissues in the wavelength range from 400 to 2000 nm. J Physics D-Applied Physics 2005;38:2543–2555.
Simpson CR, Kohl M, Essenpreis M, Cope M. Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique. Phys Med Biol 1998;43:2465–2478.
0
浏览量
71
Downloads
1
CSCD
关联资源
相关文章
相关作者
相关机构